Heat Mat Underfloor Heating

Call 01444 247020 to speak to an advisor or find your nearest stockist

  • Home
  • About Us
    • Why Choose Heat Mat?
    • Partners and Accreditations
    • Contact Heat Mat
    • Sustainable Living with Electric Underfloor Heating
    • Heat Mat Careers
    • Case Studies
    • Heat Mat Supporting Motor Neurone Disease
    • Press Area
  • Sustainable Living
  • Product Range
    • Underfloor Heating Mats
    • Underfloor Heating Cables
    • Underlaminate Heating
    • Underfloor Heating Thermostats
    • Thermal Insulation Board
    • Ice & Snow Systems
    • Accessories
    • Product Factsheets
    • Product Range Brochures
  • FAQs
    • Heat Mat FAQs
    • Instruction Downloads
    • Heat Mat Glossary
  • Blog
  • Contact Us

Heat Mat PipeGuard

You are here: Home » Product Range » Ice & Snow Systems » Heat Mat PipeGuard

  • Heat Mat PipeGuard
  • Technical Specification
  • Further Info

Easy prevention of frozen boiler condensate pipes

Designed to prevent frozen condensate pipes in the most extreme conditions, Heat Mat PipeGuard is a simple to fit solution which stops frozen, cracked and damaged pipes and ensures water keeps flowing down to -25°C. Once installed Heat Mat PipeGuard automatically ensures heat is applied to the pipe when the temperature drops close to freezing, and switches off again to save energy once the pipe has reached a safe temperature.

  • Ready made unit, simply connect to power supply
  • Simple to install, can be quickly zip-tied in place

  • Integrated thermostat to ensure energy efficiency

  • Monitors pipe temperature, rather than air temperature, to minimise running costs

  • Once covered with insulation the entire product is hidden from view, reducing potential damage or vandalism
  • Maintenance free and supplied with a 10 year warranty
  • Fully earthed for electrical safety

  • Developed for use in Scandinavia where extreme winter conditions are a common occurrence

Heat Mat PipeGuard Technical Specification 

Application  Frost protection of metallic and non-metallic water pipes 
Heating Element  Dual conductor constant Wattage heating wire 
Voltage  230V +/-10%
Output per meter 14Watts
Output Range 19-567Watts
Amprating 3amp
Sensor  Integrated thermal sensor
Start up temperature +3ºC

Cut out temperature 

+13ºC
Insulation Expanded low density polyethylene
IP Rating IPX7
Earth protection 100% earth shielded
Cable flexibility Minimum allowable cable radius is 30mm
Dimensions  1.4m to 45.0m
Coldtail lead 1.35m
Fixings  Supplied with zip tie
Warning Stickers Included within pack

Chosing the right cable for your pipe

PipeGuard Length Suitable for 10-22mm pipes of the following lengths Suitable for 23-38mm pipes of the following lengths
1.4m 0.7m-1.4m 0.7m-1.2m
2.0m 1.5m-2.0m 1.3m-1.8m
4.0m 2.1m-4.0m 1.9m-3.6m
8.0m 4.1m-8.0m 3.7m-7.2m
10.5m 8.1m-10.5m 7.3m-9.4m
14.0m 10.6m-14.0m 9.5m-12.6m
18.5m 14.1m-18.5m 12.7m-16.7m
22.5m 18.6m-22.5m 16.8m-20.2m
38.0m 22.6m-38.0m 20.3m-34.2m
45.0m 38.1m-45.0m 34.3m-40.5m

Wiring

The unit must be powered by an RCD protected supply, either from the boiler if suitable or from a separate 3amp rated fused spur. A drip loop should be introduced if the power supply is below any section of the heating cable.

Installation

If installing onto plastic pipes we recommend wrapping the pipe with an aluminium foil tape first to help dissipate heat. The PipeGuard unit should be loosely zip-tied into place atapproximately 500mm intervals with the thermostat resting beneath the pipe where the pipe exits the property. The heating cable should run beneath the pipe for pipes up to 22mm in diameter, and spiralled around the pipe for pipes measuring 23-38mm. Once the unit is in place suitable pipe insulation should be used to lag the pipe, this should be zip-tied into place and the electrical warning stickers should be placed at intervals of 3m.

 

Choosing the right cable for your pipe:

For pipes up to 22mm in diameter the cable can be run along the base of the pipe or spiralled around it. For larger pipes the cable must be spiralled around to provide even heat coverage. The table below shows the pipe lengths that each Heat Mat PipeGuard unit can protect:

For longer pipes multiple Heat Mat PipeGuard units can be used together. If installing onto non-metallic pipes we recommend covering the pipe with aluminium foil to aid the heat spread, and it is always advisable to insulate the pipe after installing the Heat Mat PipeGuard unit. The heating cable can be affixed with zip-ties, or strong tape.

Protection against costly call out charges

Costing from as little as £50 to purchase and designed to be simple to install, Heat Mat PipeGuard represents fantastic value for money. It prevents your boiler stopping or breaking down due to a frozen condensate pipe, and also ensures against the costly call out charges associated with dealing with these issues.

Very low running costs 

With it's dedicated thermostat monitoring the pipe temperature the system ensures it only provides heat when required, ensuring it would normally cost less than 50p per meter per year to operate; significantly less than some alternative systems.

Fit and forget

Once the unit is installed no maintenance is required and with its 10 Year Warranty you can be confident it will protect your pipes through the worst the British weather has to throw at us.

Designed for Scandinavian winters

Heat Mat PipeGuard is designed to cope with the extreme cold of Scandinavian winters and is reassuringly over-engineered for the very coldest British weather. Internal pipe heating systems are also available where insulation can not be added to the outside of the pipe. Please contact us for more details.


 

 

Download the Heat Mat PipeGuard Factsheet

Heat Mat PipeGuard Features

  • A simple to install product to protect against frozen condensate pipes 
  • Protects pipes in temperatures down to minus 25oC
  • Integrated thermostat monitors the pipe temperature to provide fully automated protection
  • Ready made maintenance free unit which can be simply zip-tied in place
  • Operating costs are normally less than 50p per meter per year
  • Also suitable for use to prevent frozen water pipes and taps
  • Bespoke sizes and outputs can be supplied for special projects 
  • Internal condensate pipe heaters are also available where required 
  • Designed and manufactured in Denmark and supplied with a 10 Year Warranty

Suitable for:

Boiler condensate pipes

External water pipes

Water pipes in lofts and outbuildings

Waste pipes

Heat Mat Ice and Snow

Prevention is better
than cure

If you are worried about the coming winter and want to speak to a Heat Mat advisor about the best solutions for you call us on:

01444 247020

Find all contact details here

  • Heat Mat Underfloor Heating Product Range
    • Underfloor Heating Mats
    • Underfloor Heating Cables
    • Underlaminate Heating
    • Underfloor Heating Thermostats
    • Thermal Insulation Board
    • Ice & Snow Systems
      • Heat Mat PipeGuard
      • Gutter Protection
      • Driveway De-icing
      • Roof Protection
      • Trace Heating
    • Accessories
    • Product Factsheets
    • Product Range Brochures

Download Pipeguard Factsheet

Download Ice & Snow Product Range Brochure

  • Privacy Policy
  • Terms & Conditions
  • Tel: 01444 247020
  • Email: sales@heatmat.co.uk
  • Heatmat Lifetime Warranty
  • Trading Standards Buy with Confidence Mark
  • 17th Edition Compliant
  • EMC Safe
  • Met EU consumer safety, health or environmental requirements
  • strategic & technical energy consultancy
  • BEAB approved
  • BEAB approved factory
  • Further BEAB approval
  • Semco
  • The Title Association

© Copyright Heat Mat Ltd 2010 Registered office: Ashwyn Business Centre, Marchants Way, Burgess Hill, West Sussex, RH15 8QY

Registered in England. Company registration number: 4905464 VAT no: GB 855 7131 15 Design by GSB Associates.